| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184 |
- # Plustek-SANE Backend configuration file
- # For use with LM9831/2/3 based USB scanners
- #
- # each device needs at least two lines:
- # - [usb] vendor-ID and product-ID
- # - device devicename
- # i.e. for Plustek (0x07B3) UT12/16/24 (0x0017)
- # [usb] 0x07B3 0x0017
- # device /dev/usbscanner
- # or
- # device libusb:bbb:ddd
- # where bbb is the busnumber and ddd the device number
- # make sure that your user has access to /proc/bus/usb/bbb/ddd
- #
- # additionally you can specify some options
- # warmup, lOffOnEnd, lampOff
- #
- # For autodetection use
- # [usb]
- # device /dev/usbscanner
- #
- # or simply
- # [usb]
- #
- # or if you want a specific device but you have no idea about the
- # device node or you use libusb, simply set vendor- and product-ID
- # [usb] 0x07B3 0x0017
- # device auto
- #
- # NOTE: autodetection is safe, as it uses the info it got
- # from the USB subsystem. If you're not using the
- # autodetection, you MUST have attached that device
- # at your USB-port, that you have specified...
- #
- [usb]
- #
- # options for the previous USB entry
- #
- # switch lamp off after xxx secs, 0 disables the feature
- # (can also be set via frontend)
- option lampOff 300
- # warmup period in seconds, 0 means no warmup, -1 means auto-warmup
- # (can also be set via frontend)
- option warmup -1
- # 0 means leave lamp-status untouched, not 0 means switch off
- # on sane_close
- # (can also be set via frontend)
- option lOffOnEnd 1
- #
- # options to tweak the image start-position
- # (WARNING: there's no internal range check!!!)
- #
- # for the normal scan area
- #
- option posOffX 0
- option posOffY 0
- # for transparencies
- option tpaOffX 0
- option tpaOffY 0
- # for negatives
- option negOffX 0
- option negOffY 0
- #
- # for setting the calibration strip position
- # (WARNING: there's no internal range check!!!)
- # -1 means use built in
- # (can also be set via frontend)
- option posShadingY -1
- option tpaShadingY -1
- option negShadingY -1
- #
- # to invert the negatives, 0 disables the feature
- #
- option invertNegatives 0
- #
- # to disable the internal sensor speedup function,
- # 1 disables the feature
- #
- option disableSpeedup 0
- #
- # to save/restore coarse calibration data
- # (can also be set via frontend)
- option cacheCalData 0
- #
- # use alternate calibration routines
- #
- option altCalibration 0
- #
- # for skipping whole calibration step
- #
- option skipCalibration 0
- #
- # for skipping entire fine calibration step
- # coarse calibration is done
- #
- option skipFine 0
- #
- # discard the result of the fine white calibration
- #
- option skipFineWhite 0
- #
- # some scanners have a dark calibration strip, in
- # general this one should be used for calibration.
- # As this could cause some trouble, this option
- # overrides that and the dark calibration will be
- # done by switching the lamp off
- #
- option skipDarkStrip 0
- # for replacing the gain values found during coarse
- # calibration
- # (can also be set via frontend)
- option red_gain -1
- option green_gain -1
- option blue_gain -1
- # for replacing the offset values found during coarse
- # calibration
- # (can also be set via frontend)
- option red_offset -1
- option green_offset -1
- option blue_offset -1
- #
- # for replacing the default lampoff settings, this
- # works only for CIS devices like CanoScan LiDE20
- # (can also be set via frontend)
- option red_lampoff -1
- option green_lampoff -1
- option blue_lampoff -1
- #
- # for adjusting the default gamma values
- # (can also be set via frontend)
- option redGamma 1.0
- option greenGamma 1.0
- option blueGamma 1.0
- option grayGamma 1.0
- #
- # to enable TPA (EPSON or UMAX, if autodetection fails)
- # 0 means default behaviour as specified in the internal tables
- # 1 means enable (needed for UMAX 3450)
- option enableTPA 0
- #
- # model override functionality, currently only available for
- # Mustek devices, using NSCs' vendor ID: 0x0400 and
- # also their product ID: 0x1000 (LM9831) 0x1001 (LM9832)
- #
- # mov/PID | 0x1000 | 0x1001
- # ---------------------------------------
- # 0 (default)| BearPaw1200 | BearPaw 2400
- # 1 | ignored | BearPaw 1200
- #
- option mov 0
- #
- # and of course the device-name
- #
- # device /dev/usbscanner
- device auto
- #
- # to define a new device, start with a new section:
- # [usb]
- #
|